Liquid Level Probe

Measure and display refrigerant or oil level in a vessel

Features

  • 3/4″ MPT or 1 1/4″ -12 Rotalock connection
  • Continuous accurate measurement
  • DIN cable connector
  • 3.6m, 3-wire 20 AWG cable
  • Options Include: LCD Display, 1-6V output
  • For units, which may be subjected to condensation, a sealed option is available. Note, however that the LCD display is not available with this option

Note: Liquid Level Probe units are not suitable for outdoor use

Enquiry Form:

Max Working Pressure 90 Barg (1305 PSIg)
Operating Temperature Range -40°C to +70°C (-40°F to +158°F)
Refrigerant Compatibility A2L, CO2, HC, HCFC, HFC and HFO where materially compatible
Sizes Available N/A
Product Certification CE/UKCA marked for Low Voltage and EMC Directives
Filename Download File
LLP Assem Rotalock.step Download (170.56 KB)
Filename Download File
LLP Assem Cust revA.pdf Download (106.25 KB)